Customization: | Available |
---|---|
Type: | Self-Starting Diesel Generator |
Installation Method: | Fixed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
DIESEL GENERATOR SET | ||||||||
Gensets Model | KH-320GF | |||||||
Prime Power | 320KW/400KVA | |||||||
Standby Power | 360KW/450KVA | |||||||
Rated Voltage(V) | 380/220 | |||||||
Rated Frequency(Hz) | 50 | |||||||
Rated Speed (RPM) | 1500 | |||||||
Power Factor(COS¢) | 0.8(lagging) | |||||||
ENGINE DATA | ||||||||
Engine brand | PERKINS | |||||||
Engine model | 2206C-E13TAG3 | |||||||
Number of Cylinders | 6 | |||||||
Cylinder arrangement | Vertical In-line | |||||||
Cycle | Four stroke | |||||||
Aspiration | Turbocharged and air-to-air charge cooled | |||||||
Fuel System | Direct Injection | |||||||
Bore×Stroke (mm×mm) | 130*157 | |||||||
Displacement (Liter) | 12.5 | |||||||
Speed Governor | Electronic | |||||||
Compression ratio | 16.3:1 | |||||||
Total lubrication system capacity | 40L | |||||||
Total coolant capacity | 51.4L | |||||||
Cooling System | Water-cooled | |||||||
Starting Method | DC 24V electrical starting | |||||||
ALTERNATOR DATA | ||||||||
Alternator brand | STAMFORD | |||||||
Alternator model | HCI444FS | |||||||
Number of Phase | 3 | |||||||
Connecting Type | 3 Phase and 4 Wires | |||||||
Number of Bearing | Single | |||||||
Protection Grade | IP23 | |||||||
Altitude | ≤1000m | |||||||
Exciter Type | Brushless, Self-exciting, AVR &100% Copper winding wire | |||||||
Insulation Class | H | |||||||
Telephone Influence Factor (TIF) | ≤50 | |||||||
Telephone Harmonic Factor(THF) | ≤2% | |||||||
Steady State Voltage Regulation | ±0.5%~±1.0% | |||||||
Transient State Voltage Regulation | ≤-15%~+20% |