Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)

Product Details
Customization: Available
After-sales Service: Global Warranty
Warranty: 1 Year or 1000 Hours
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
100
Year of Establishment
2004-01-08
  • Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)
  • Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)
  • Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)
  • Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)
  • Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)
  • Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)
Find Similar Products

Basic Info.

Model NO.
KH-1600GF
Type
Self-Starting Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Brushless Excititation
Transport Package
Plywood Case or PE Film
Specification
5770*2800*3520mm(L*W*H)
Trademark
Kaitong
Origin
Jiangsu, China
HS Code
8502131000
Production Capacity
2000 Sets Per Year

Product Description

Factory OEM Powerful 1600kw/2000kva Diesel Generator Set Powered by British Perkins (4016TAG2A)
 
PRODUCTS DETAILS
DIESEL GENERATOR SET
Genset Model KH-1600GF
Prime Power 1600KW/2000KVA
Standby Power 1760KW/2200KVA
Rated Voltage (V) 400
Rated Current (A) 2886
Rated Frequency (Hz) 50
Rated Speed (RPM) 1500
Power Factor (COS¢) 0.8 (lagging)
ENGINE DATA
Engine Brand Perkins
Engine Model 4016TAG2A
No. of Cylinders 16
Cylinder Arrangement 60° Vee
Cycle 4 Stroke
Aspiration Turbocharged
Fuel System Direct Injection
Bore*Stroke (mm*mm) 160*190
Displacement (Liter) 61.123
Compression Ratio 13.6:1
Cooling System Water-Cooled
Starting Method DC 24V Electrical Starting
Lubricating Oil Capacity Sump Maximum (Litres) 214
Total Cooltant Capacity - Engine Only (Liter) 95
Fuel Consumption (L/h) 100% 434
75% 316
50% 210
ALTERNATOR DATA
Alternator Brand Stamford
Alternator Model PI734F
Connecting Type 3 Phases and 4 Wires
Number of Bearing Single
Production Grade IP23
Altitude ≤ 1000m
Exciter Type Brushless, Self-exciting, AVR & 100% Copper Winding Wire
Insulation Class H
Telephone Influence Factor (TIF) ≤ 50
Telephone Harmonic Factor (THF) ≤ 2%
Voltage Regulation, Steady State 1.00%
Transient State Voltage ≤ -15% ~ +20%

COMPANY
Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)

Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)

Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)
OEM & SERVICE
Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)

Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)
TYPICAL CASES
Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)
Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)

EXHIBITION
Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)
Factory OEM Powerful 1600kw/2000kVA Diesel Generator Set Powered by British Perkins (4016TAG2A)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier